  • Akimov, A.V.; Logachev, P.V.; Bochkov, V.D.; Bochkov, D.V.; Dyagilev, V.M.; Ushich, V.G. (Вопросы атомной науки и техники, 2008)
    The circuit of modulator, serving to supply inductive-resistive load in double-pulse mode with currents up t10 kA and pulse duration of 300 ns, is described. As switching components TPI1-10k/50 thyratrons (pseudospark ...
  • Akimov, A.V.; Kazarezov, I.V. (Вопросы атомной науки и техники, 2001)
    While the operation of modulator to the pulsed transformer of klystron-5045, current through the primary winding of the pulse transformer (PT) continues to flow even upon the end of the klystron voltage operating pulse. ...
  • Akimov, A.V.; Bak, P.A.; Kazarezov, I.V.; Korepanov, A.A. (Вопросы атомной науки и техники, 2006)
    The results of cold cathode TPI1-10k/50 thyratron parameters at voltage up to 50 kV, current up to 10 kA and pulse duration of hundred ns are described. The optimal parameters of thyratron power supply and pulse driver ...
  • Akimov, A.V.; Bak, P.A.; Kazarezov, I.V.; Pachkov, A.A. (Вопросы атомной науки и техники, 2004)
    The 200 kV electron gun modulator power supply based on the half-bridge converter providing the high frequency partial charge of the capacitive energy storage element is described. The algorithm developed for the power ...
  • Akimov, A.V.; Akimov, V.E.; Bak, P.A.; Kazarezov, I.V.; Kot, N.H.; Chupyra, A.G.; Rezakov, A.M.; Yudin, V.D. (Вопросы атомной науки и техники, 2001)
    In the complex VEPP-5 preinjector the klystrons are supplied by the modulators with a pulse power of 150 MW, a voltage of 47.5 kV, a primary current of 6.3 kA and a pulse duration of 3.5 ms. During the long time operation ...
  • Gurov, S.M.; Akimov, A.V.; Anchugov, O.V.; Batrakov, A.M.; Belikov, O.V.; Bekhtenev, E.A.; Burenkov, D.B.; Cheblakov, P.B.; Cherepanov, V.P.; Chernyakin, A.D.; Cheskidov, V.G.; Churkin, I.N.; Elkaer, A.; Erokhin, A.I.; Fliller, R.; Gorchakov, K.M.; Gurov, D.S.; Ganetis, G.; Hseuh, H.; Karnaev, S.E.; Karpov, G.V.; Kiselev, V.A.; Kobets, V.V.; Konstantinov, V.M.; Kolmogorov, V.V.; Korepanov, A.A.; Kuper, E.A.; Kuzminykh, V.S.; Levichev, E.B.; De Long, J.; Mamkin, V.R.; Medvedko, A.S.; Meshkov, O.I.; Nefedov, N.B.; Neyfeld, V.V.; Okunev, I.N.; Petrov, V.V.; Petrichenkov, M.V.; Philipchenko, A.V.; Polyansky, A.V.; Pureskin, D.N.; Rakhimov, A.R.; Ruvinskiy, S.I.; Schegolev, L.M.; Semenov, A.M.; Senkov, D.V.; Serednyakov, S.S.; Shaftan, T.V.; Sharma, S.; Shichkov, D.S.; Singh, O.; Shiyankov, S.V.; Shvedov, D.A.; Sinyatkin, S.V.; Smaluk, V.V.; Sukhanov, A.V.; Tian, Y.; Utkin, A.V.; Willeke, F.; Yaminov, K.R.; Yong, H. (Вопросы атомной науки и техники, 2012)
    The National Synchrotron Light Source II is a third generation light source under construction at Brookhaven National Laboratory. The project includes a highly optimized 3 GeV electron storage ring, linac pre-injector and ...
  • Akimov, A.V.; Akimov, V.E.; Bak, P.A.; Kazarezov, I.V.; Korepanov, A.A.; Kulenko, Ya.V.; Ribitskaia, T.V.; Kuznetsov, G.I.; Pachkov, A.A.; Tiunov, M.A. (Вопросы атомной науки и техники, 2006)
    The modified pulsed electron beam source on voltage 200 kV and current 10 A with half-height pulse duration 2.5 ns and repetition rate 50 Hz is described. The source gun has been performed on the base of impregnated ...
  • Akimov, A.V.; Bak, P.A.; Gusev, E.A.; Kazarezov, I.V.; Kot, N.H.; Chupyra, A.G.; Petrov, S.P.; Yudin, V.D. (Вопросы атомной науки и техники, 2004)
    For the VEPP-5 injection complex klystrons (5045, SLAC Lab., USA) power supply the four modulators producing a pulse voltage of 23.5 kV, a current of 6.3 kA, a pulse-top-duration of 3.7 µs are used. The modulator scheme ...